Aqualung recall notice

General banter about diving and why we love it.
Post Reply
User avatar
oregondiver
Submariner
Posts: 579
Joined: Wed Jul 23, 2008 7:16 am

Aqualung recall notice

Post by oregondiver »

Aqualung recall notice.
I just got this and thought I should pass on.

http://www.cpsc.gov/cpscpub/prerel/prhtml08/08393.html

FOR IMMEDIATE RELEASE
September 10, 2008
Release #08-393 Firm's Recall Hotline: (877) 253-3483
CPSC Recall Hotline: (800) 638-2772
CPSC Media Contact: (301) 504-7908

Aqua Lung Recalls Scuba Regulators and Adapters Due to Drowning Hazard
WASHINGTON, D.C. - The U.S. Consumer Product Safety Commission, in cooperation with the firm named below, today announced a voluntary recall of the following consumer product. Consumers should stop using recalled products immediately unless otherwise instructed.

Name of Product: Titan DIN 1st Stage Scuba Regulators and Titan/Conshelf DIN Scuba Adaptors

Units: About 6,000

Manufacturer: Aqua Lung USA, of Vista, Calif.

Hazard: Over-tightening of the DIN retainer by a technician during installation can result in the retainer breaking under pressure, a rapid escape of air from the scuba cylinder, and the regulator detaching from the scuba cylinder. This poses a drowning hazard to divers.

Incidents/Injuries: The firm has received one report of a DIN retainer breaking under pressure. No injuries have been reported.

Description: The recalled regulators have a brass DIN retainer manufactured prior to June 2006. The recalled Aqua Lung Titan Din 1st Stage regulators have serial numbers lower than 6062501 stamped on the side of the regulator’s body. Recalled Titan/Conshelf DIN adaptors are marked “300 BAR MAX” on the side of the part. DIN adaptors marked “300 BAR MAXI” are not included in this recall.

Sold at: Authorized Aqua Lung dealers nationwide from January 1997 through September 2008 for about $300 to $450 for the scuba regulators or $70 for DIN adaptors sold separately.

Manufactured in: France

Remedy: Consumers should immediately stop using the recalled diving regulators and DIN adaptors and return them to any authorized Aqua Lung dealer for a free replacement DIN retainer.

Consumer Contact: For additional information, contact Aqua Lung toll-free at (877) 253-3483 between 8 a.m. and 5 p.m. PT Monday through Friday, or visit the firm’s Web site at http://www.aqualung.com
Discussing the Whites Fusion: "Looks like you are wearing a startrek leotard with bunched-up undies..." -Airsix

"fins are like shoes....you can never have enough pairs." -Lizard0924
User avatar
Kirby
Aquaphile
Posts: 123
Joined: Mon Jan 30, 2006 5:06 pm

Re: Aqualung recall notice

Post by Kirby »

Thats interesting, happen to have one of these regs. It went into an uncontrolled 1st stage purge during a dive at 85 ft right after I had it serviced. I went to my sling and all was cool, but was definitely a stressful moment. My dive buddy said I put on a spectacular bubble show as my tank emptied. It did not separate from the tank however. Thanks for the recall notification, will definitely get it taken care of ASAP.

Kirby
Hi, My name is Kirby, and I am addicted to Nitrogen Narcosis.
User avatar
Ken G
I've Got Gills
Posts: 1486
Joined: Sun Apr 02, 2006 10:07 pm

Re: Aqualung recall notice

Post by Ken G »

http://www.cpsc.gov/cpscpub/prerel/prhtml08/08402.html

FOR IMMEDIATE RELEASE
September 17, 2008
Release #08-402

Firm's Recall Hotline: (877) 253-3483
CPSC Recall Hotline: (800) 638-2772
CPSC Media Contact: (301) 504-7908


Aqua Lung America Recalls Apeks Scuba Diving Regulators Due to Drowning Hazard
WASHINGTON, D.C. - The U.S. Consumer Product Safety Commission, in cooperation with the firm named below, today announced a voluntary recall of the following consumer product. Consumers should stop using recalled products immediately unless otherwise instructed.

Name of Product: Apeks Second Stage Scuba Regulators

Units: About 25,000

Distributor: Aqua Lung America of Vista, Calif.

Manufacturer: Apeks Marine Equipment Ltd., of Blackburn, England

Hazard: These regulators can be missing the diaphragm cover which can cause the diaphragm to become displaced during a dive, allowing water to enter the scuba regulator. This poses a drowning hazard to divers.

Incidents/Injuries: None.

Description: This recall involves Apeks TX, ATX, and XTX second stage regulators that have never been serviced. Apeks and TX, ATX, or XTX is printed on the regulator.

Sold at: Authorized Apeks dealers nationwide from February 2000 through June 2008 for between $420 and $1,450.

Manufactured in: England

Remedy: Consumers should immediately stop diving with these regulators and visit an authorized Apeks dealer for a free inspection and free installation of a diaphragm cover, if the cover is missing.

Consumer Contact: For additional information, contact Aqua Lung toll-free at (877) 253-3483 between 8 a.m. and 5 p.m. PT Monday through Friday, or visit the company’s Web site at http://www.aqualung.com